CF ChatterFix
Safety Inspection

Lab Chemical & Eyewash Inspection

Emergency eyewash and safety showers are the last line of defence in a lab, and they fail silently. Stagnant supply lines grow biofilm, valves seize, and access gets blocked by stored equipment — none of which is apparent until someone needs the station within the seconds that matter for a chemical splash. Alongside that, chemical inventories accumulate their own hazard: peroxide-forming chemicals past shelf life become shock-sensitive.

Interval Monthly
Est. Duration 1.0 hr
Steps 5
Applies To Education & Campus Facilities

The Procedure

The steps ChatterFix schedules for this PM. Every step is a checkable item on the work order — a technician can speak their way through it without touching a keyboard.

  1. Flush every eyewash and safety shower; record flow, temperature and duration
  2. Verify chemical storage segregation and that containers are labelled and dated
  3. Check that chemicals past shelf life are removed, especially peroxide formers
  4. Confirm SDS access and spill kit contents in every lab
  5. Verify fume hoods carry a current certification label

Why This PM Exists

Emergency eyewash and safety showers are the last line of defence in a lab, and they fail silently. Stagnant supply lines grow biofilm, valves seize, and access gets blocked by stored equipment — none of which is apparent until someone needs the station within the seconds that matter for a chemical splash. Alongside that, chemical inventories accumulate their own hazard: peroxide-forming chemicals past shelf life become shock-sensitive.

What Skipping It Looks Like

An eyewash that has never been flushed delivers contaminated water into an injured eye. A blocked shower is unreachable exactly when it is needed. On the storage side, aged peroxide formers and lapsed segregation build a hazard that typically surfaces during a lab clear-out — often handled by whoever is least equipped to recognise it.

Setting the interval

Monthly activation and flush of every station, with an annual full performance test against the standard. Chemical inventory review at least termly, and immediately before any lab clear-out or relocation.

Equipment This Covers

Common Questions

How often should this PM run?
Monthly. Monthly activation and flush of every station, with an annual full performance test against the standard. Chemical inventory review at least termly, and immediately before any lab clear-out or relocation.
How long does it take?
Budget about 1.0 hour for a technician working to the standard procedure. ChatterFix uses that estimate for capacity planning, then learns your plant's actual time from completed work orders.
What happens if we skip it?
An eyewash that has never been flushed delivers contaminated water into an injured eye. A blocked shower is unreachable exactly when it is needed. On the storage side, aged peroxide formers and lapsed segregation build a hazard that typically surfaces during a lab clear-out — often handled by whoever is least equipped to recognise it.
Can I use this checklist in ChatterFix?
Yes — this exact procedure ships in the Education & Campus Facilities industry pack. Pick your industry at signup and it is scheduled on the right assets automatically, with no configuration.