A tablet press is locked out before punches, the feeder, and the force sensor are looked at. Weight, thickness, and speed belong to the released process, not to this inspection.

Tracked Components 4
Scheduled PMs 7
Industries Pharmaceutical & Life Sciences

Components To Track

ChatterFix builds these as child assets under tablet press, so failure history and PM completions attach to the component that actually failed — not just to the machine.

How Tablet Press Actually Fails

The failure modes worth designing a maintenance schedule around — in rough order of what they cost when they happen.

  • Chipped or worn punches left in the turret
  • A force sensor nobody compared with the released check
  • A feeder or turret guard off at release
  • Binding that gets 'fixed' by changing speed
  • A punch past the wear limit still in the set

What To Measure

Recording that a PM was "done" tells you nothing next quarter. These are the readings that let you see a failure coming — and the reason ChatterFix captures measurements against the asset rather than just completions.

  • Punch and die condition against the site wear limit
  • The force-sensor check the released procedure names
  • Guard presence before release
  • That weight, thickness, and speed were not changed
  • Quarantine of an out-of-limit punch

Spares Worth Stocking

The parts whose absence turns a short repair into a long outage.

Preventive Maintenance Schedule

The PMs ChatterFix schedules against this equipment, with intervals and time estimates.

Common Questions

What maintenance does tablet press need?
ChatterFix schedules 7 routines against this asset: co2 sensor panel calibration record (monthly), feeder switch enclosure inspection (quarterly), filling isolator glove and pressure check (weekly), fire suppression panel gauge check (monthly), press die inspection & tonnage verification (quarterly), tablet press force and punch condition (weekly), tyre rotation & pressure check (quarterly). The readings that matter most are punch and die condition against the site wear limit.
How does tablet press usually fail?
The most common modes are: chipped or worn punches left in the turret; a force sensor nobody compared with the released check; a feeder or turret guard off at release; binding that gets 'fixed' by changing speed; a punch past the wear limit still in the set. Most of these degrade gradually rather than failing outright, which is what makes interval-based inspection worthwhile.
What spare parts should we stock?
Punch set the site standardizes on, Die, Feeder parts the OEM lists, Force-sensor cable, Guard fasteners. The test is lead time, not cost: stock the part whose absence turns a two-hour repair into a two-week outage, even if it is cheap.
Can I track this in ChatterFix?
Yes. Pick your industry at signup and tablet press is created as an asset with its 4 tracked components, with its PM schedule already attached. Technicians then log readings and findings against it by voice rather than typing them in.